DUAL MAIN WINDING TYPE:
Remove the generator end cover (page 7-15).
Remove the nuts and disconnect the main winding
terminal
winding terminal
Measure the resistance between the stator side
terminals according to the table below.
If the specified resistance is zero or infinity, replace the
stator.
FIELD WINDING INSPECTION
Remove the generator end cover (page 7-15).
Start the engine and measure the DC voltage at the
brush terminals.
EG3600, EG4000:
EG4500, 5000, 5500, 6500:
, main winding terminal
, main winding terminal
EG4000 (LDH type)
EG4000 (LDH type)
EG6500 (LDH, LTH type)
Field winding terminal
(Red) and
(White)
Field winding terminal
(Red) and
(White)
GENERATOR/CHARGING SYSTEM
, main
.
Main Winding terminal
(Red) and
(Gray) and
Main Winding terminal
(Red) and
(Gray) and
Main Winding terminal
(Red) and
(Gray) and
Voltage
(VDC)
About 25
Voltage
(VDC)
About 30
Resistance (Ω)
(at 20 °C/68 °F)
(White)
0.6
(Blue)
0.6
Resistance (Ω)
(at 20 °C/68 °F)
(White)
0.4
(Blue)
0.4
Resistance (Ω)
(at 20 °C/68 °F)
(White)
0.3
(Blue)
0.3
7-17