82Z30000.book 4 ページ 2010年6月25日 金曜日 午後5時50分
GENERATOR/CHARGING SYSTEM
GENERATOR SYSTEM TROUBLESHOOTING
No or Low AC Output
Remove the generator end cover (page 7-15)
and inspect the stator winding (1) for
discoloration.
Normal
Check the engine speed.
STANDARD:
Except SH, SKH, LDH, LTH type:
-1
3,000 ± 100 min
SH, SKH, LDH, LTH type:
3,600 ± 100 min
-1
Normal
Measure the voltage of the main winding
(page 7-15).
Abnormal
Measure the voltage of the field winding
(page 7-17).
Normal
Go to page 7-5
7-4
Discolored
(1)
Abnormal
(rpm)
(rpm)
Normal
Abnormal
Replace the stator (page 7-13).
Adjust the governor (page 6-3).
Open circuit in wire harness between the
receptacle and main winding.
Go to page 7-6