Honda EG3600CX Manual page 129

Hide thumbs Also See for EG3600CX:
Table of Contents

Advertisement

82Z30000.book 18 ページ 2010年6月25日 金曜日 午後5時50分
GENERATOR/CHARGING SYSTEM
If the specified voltage is not obtained, stop the engine
and remove the screw (1) and brush holder (2).
Measure the resistance between the slip rings (2).
EG3600, 4000
EG4500, 5000
EG5500, 6500
If the specified resistance is zero or infinity, clean the
slip rings or replace the rotor.
D-AVR UNIT INSPECTION
Remove the D-AVR cover (page 10-3).
Measure the resistance between the D-AVR unit (1)
No.7 terminal and No.8 terminal.
• When measuring the resistance, connect the tester
probes to the terminals.
Do not connect the probes to the soldered part.
Resistance:
If the specified resistance is zero or infinity, replace the
D-AVR.
EXCITER WINDING INSPECTION
Remove the generator end cover (page 7-15).
Start the engine and measure the AC voltage between
the exciter winding 3P connector
terminal and No.3 (Blue) terminal with connector
connected.
STANDARD VOLTAGE: About 90 VAC
7-18
Resistance (Ω)
Type
(at 20 °C/68 °F)
47
60
62
1.0 kΩ maximum
No.1 (Blue)
No.8
No.7
(2)
(1)
(1)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents