Flogi Quiesce Timeout; Restrictions; Enabling Flogi Scale Optimization And Quiesce Timeout - Cisco MDS 9000 Series Configuration Manual

Hide thumbs Also See for MDS 9000 Series:
Table of Contents

Advertisement

FLOGI Quiesce Timeout

FLOGI Quiesce Timeout
The FLOGI Quiesce Timeout feature causes the FLOGI process to delay notifications to the other Fibre
Channel services such as Routing Information and Fibre Channel Name Server when a device logs out from
a fabric or when an interface goes down. If the device logs back to the fabric within the FLOGI quiesce timeout
value, the FLOGI Accept can be immediately returned without the other Fibre Channel services being notified.
This feature must be disabled by setting the timeout value to zero when there are devices in the fabric that
can share a pWWN at different times by logging into different switches within the fabric during failover
situations.

Restrictions

• Downgrading from Cisco MDS NX-OS Release 8.1(1) to an earlier release is not supported when FLOGI
• In Cisco MDS NX-OS Releases 8.1 and Release 8.2, the default FLOGI quiesce timeout value is 2000
• This feature is supported on all MDS switches, except Cisco MDS 9250i Multiservice Fabric Switch and
• Cisco DCNM and SNMP support is not available for this feature.
• This feature is supported only on the Fibre Channel ports on the Cisco MDS 24/10 port SAN Extension

Enabling FLOGI Scale Optimization and Quiesce Timeout

To enable FLOGI scale optimization and quiesce timeout, perform the following steps:
Step 1
Enter global configuration mode:
switch# configure terminal
Step 2
Enable FLOGI scale optimization:
switch(config)# flogi scale enable
Step 3
Set the FLOGI quiesce timeout value to retain device login information:
switch(config)# flogi quiesce timeout milliseconds
For information on the default FLOGI quiesce timeout value, see the
Step 4
Exit global configuration mode:
switch(config)# exit
Cisco MDS 9000 Series Fabric Configuration Guide, Release 8.x
210
Scale Optimization is enabled. This feature must be disabled before downgrading. For more information
on disabling this feature, see the
ms.
However, starting with Cisco MDS NX-OS Release 8.3(1), the default FLOGI quiesce timeout value
was changed from 2000 ms to 0 ms. Any configured FLOGI quiesce timeout value will be maintained
on upgrading. If the FLOGI quiesce timeout value is not configured when upgrading to Cisco MDS
NX-OS Releases 8.3(1) or later release, the new default value of 0 ms will be used.