Configuring Ficon; About Enabling Ficon On A Vsan - Cisco MDS 9000 Series Configuration Manual

Hide thumbs Also See for MDS 9000 Series:
Table of Contents

Advertisement

Configuring FICON

Note
You cannot configure persistent FC IDs in FICON-enabled VSANs.
Cisco MDS switches have a dynamic FC ID allocation scheme. When FICON is enabled or disabled on a
VSAN, all the ports are shut down and restarted to switch from the dynamic to static FC IDs and vice versa
(see
Figure 57: Static FC ID Allocation for FICON
Configuring FICON
By default FICON is disabled in all switches in the Cisco MDS 9000 Family. You can enable FICON on a
per VSAN basis by using the Device Manager.
This section includes the following topics:

About Enabling FICON on a VSAN

By default FICON is disabled in all VSANs on the switch.
You can enable FICON on a per VSAN basis in one of the following ways:
• Use the automated setup ficon command.
See the
• Manually address each prerequisite.
See the
• Use Device Manager.
When you enable the FICON feature in Cisco MDS switches, the following restrictions apply:
• You cannot disable in-order delivery for the FICON-enabled VSAN.
• You cannot disable fabric binding or static domain ID configurations for the FICON-enabled VSAN.
• The load balancing scheme is changed to Source ID (SID)—Destination ID (DID). You cannot change
• The IPL configuration file is automatically created.
See the
Figure 57: Static FC ID Allocation for FICON, on page
Setting Up a Basic FICON Configuration, on page
About FICON, on page
245.
it back to SID—DID—OXID.
About FICON Configuration Files, on page
259).
260.
279.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 8.x
Configuring FICON
259

Advertisement

Table of Contents
loading

Table of Contents