Fitting The Certified Sensor - Honeywell Apex Technical Handbook

Gas detection system
Hide thumbs Also See for Apex:
Table of Contents

Advertisement

MAN0604_Issue 09_02-2013
2110M8030

3.1.2 Fitting the Certified Sensor

(1)
Fit the Certified Sensor to the Transmitter Unit.
Transmitter Unit
base
Certified Sensor
mounting point
Certified Sensor
Feed the sensor cable through the Certified Sensor mounting point at the front of the
Transmitter Unit base. Screw the sensor firmly into the mounting point until it is fully home.
(2)
Connect the sensor wiring.
See the following wiring table and diagram.
Terminal
Number
SK3
1
(Sensor)
2
3
4
5
SK4
1
(Comms
2
and
Power)
3
4
5
6
7
SK6
1
(Relays)
2
3
4
5
6
g
-
3. inSTAllATiOn
Function
Colour
CAN_L
White
CAN_H
Green
+V
Red
0V
Black
Screen
NET1
NET2
Ground
4 - 20mA -
4 - 20mA +
0V
+24Vdc (18-32Vdc)
Fault
Fault common
Alarm 1
Alarm 1 common
Alarm 2
Alarm 2 common
Earth
Green/Yellow
Recommended
Wire Length
40mm
40mm
40mm
40mm
40mm
60mm
60mm
50mm
50mm
50mm
50mm
50mm
50mm
50mm
50mm
50mm
50mm
50mm
25