Honeywell Apex Technical Handbook page 28

Gas detection system
Hide thumbs Also See for Apex:
Table of Contents

Advertisement

MAN0604_Issue 09_02-2013
2110M8030
Caution:
Do not force the cartridge as this may cause damage to the pins of the connecting
plugs. Twisting and pushing can bend the pins and make the cartridge inoperative.
Socket (2 off)
Locating
tab
recess
Sensor body
Note: If fitting an Oxygen cartridge ensure that the Oxygen Transducer Adaptor supplied with the
Oxygen cartridge is fitted to the Certified Sensor body. The adaptor is fitted to the sensor
body via a bayonet fitting.
(3)
Refit the cap to the Certified Sensor.
Reverse the removal procedure.
(4)
Check for correct operation of the system by carrying out the procedures described in
Chapter 4.
3. inSTAllATiOn
28
Sensor body
Cartridge fitted to sensor
body
Sensor cap
Apex
Plug
(2 off)
Locating
tab
Cartridge