DB9
Female
1 -6, 9
7 (RTS)
8 (CTS)
Note: Wire colors only apply to optional Honeywell Screen Blanking Box Cable, VM1080CABLE.
Wire colors may vary in a user-supplied cable.
The optional Honeywell Screen Blanking Box Cable, VM1080CABLE, is installed as fol-
lows:
1.
2. Connect the black wire of the cable to the unswitched side of the Screen Blanking
3. Connect the D9 serial connector to either COM1 or COM2 serial port on the Thor
User-Supplied Cable
A user-supplied cable can be used as well. Pins 7 and 8 must be connected as detailed
below. No other pins are to be connected.
PIN 5
PIN 8
DB9
Female
1 -6, 9
7 (RTS)
8 (CTS)
The user-supplied cable is installed as follows:
Thor VM3 with Microsoft Windows Embedded Compact 7 User Guide
Function with Screen Blanking Box
Not Used
Connected to Screen Blanking Box, unswitched
side
Connected to Screen Blanking Box, switched
side
Connect the gray wire of the cable to the switched side of the Screen Blanking
Box.
Box.
VM3 dock.
PIN 1
PIN 7
Function with Screen Blanking Box
Not Used
Connected to Screen Blanking Box, unswitched
side
Connected to Screen Blanking Box, switched side
Wire color
Black (see note)
Gray (see note)
Function with Switch
Not Used
Connected to Switch
Connected to Switch