Siemens SINUMERIK 840D sl Function Manual page 473

Sinumerik safety integrated
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

03.06
Remedy
F30651
Response:
Acknowledgement
Explanation
Remedy
F30652
Response:
Acknowledgement
Explanation
Remedy
© Siemens AG, 2006. All rights reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 03.2006 Edition
Re fault value = 130:
– Carry-out safety commissioning routine.
Re fault value = 1000:
– Repeat safety commissioning.
– Replace the CompactFlash Card.
Re fault value = 2000:
– Check the safety parameters on the Motor Module and adapt the
reference checksum (p9899).
Re fault value = 2003:
– Carry-out an acceptance test.
Re fault value = 9999:
– Carry-out diagnostics for the other safety-related fault that is
present.
SI MM: Synchronization with the Control Unit unsuccessful
OFF2
IMMEDIATELY (POWER ON)
The "Safety Integrated" function integrated in the drive is requesting
synchronization of the safety time slices on the Control Unit and Motor
Module. This synchronization routine was not successful.
Note:
This fault results in a STOP A that cannot be acknowledged.
Fault value (r0949, decimal):
Only for internal Siemens troubleshooting.
Carry-out a POWER ON (power off/on) for all components
– Upgrade the Motor Module software.
– Upgrade the Control Unit software.
SSI MM: Monitoring clock cycle not permissible
OFF2
IMMEDIATELY (POWER ON)
The Safety Integrated monitoring clock cycle cannot be maintained due
to the communication conditions requested in the system.
Note:
This fault results in a STOP A that cannot be acknowledged.
Fault value (r0949, decimal):
Only for internal Siemens troubleshooting.
Upgrade the Motor Module software.
10.3 Safety messages for SINAMICS S120
Diagnostics
10-473

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics s120

Table of Contents