Siemens SINUMERIK 840D sl Function Manual page 409

Sinumerik safety integrated
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

03.06
Response
Remedy
Program
continuation
27011
Parameter
Explanation
Response
Remedy
Program
continuation
27012
Parameter
Explanation
Response
© Siemens AG, 2006. All rights reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 03.2006 Edition
10.2 NCK safety alarms for Sinumerik 840D sl
Mode group not ready
Channel not ready
NC start inhibit in this channel
Interface signals are set
Alarm display
NC stop for alarm
Channel not ready
Check the tolerance for the standstill monitoring: does the value match
the precision and control dynamic performance of the axis?
If not, increase the tolerance. If yes, check the machine for damage
and repair it.
Power-down the control and power-up again
Axis %1 safely-reduced speed exceeded
%1 = axis number
The axis has moved too quickly and faster than that specified in MD
$MA_SAFE_VELO_LIMIT.
When SBH/SG is active in a configuration with a 1-encoder system, the
speed that corresponds to the encoder limit frequency was exceeded.
The axis is stopped with STOP A, C, D or E, depending on what has
been configured in MD $MA_SAFE_VELO_STOP_MODE or MD
$MA_SAFE_VELO_STOP_REACTION.
NC start inhibit in this channel
Interface signals are set
Alarm display
NC stop for alarm
If no obvious operator error has occurred: Check the value entered into
the MDs, check the SGEs: Was the correct safely-reduced speed
selected? If the MDs and SGEs are o.k., check the machine for any
damage and rectify.
Clear the alarm with the RESET key. Restart the part program.
Axis %1 safe limit position exceeded
%1 = axis number
The axis has passed the limit position entered in MD
$MA_SAFE_POS_LIMT_PLUS or MD
$MA_SAFE_POS_LIMIT_MINUS.
This axis is stopped with STOP C,D or E, according to the
configuration in MD $MA_SAFE_POS_STOP_MODE.
NC start inhibit in this channel
NC start inhibit in this channel
Interface signals are set
Alarm display
NC stop for alarm
Diagnostics
10-409

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics s120

Table of Contents