Data Description
8.2 Parameters for SINAMICS S120
General diagnostic parameters on the CU
r9710[0...1]
SI motion, diagnostics result list 1
Displays result list 1 where for a crosswise data comparison with the control,
led to an error.
[0]: Result list (control)
[1]: Result list (drive)
Units:
Default value:
Bit
Signal name
00
Actual value > Upper limit SBH
01
Actual value > Lower limit SBH
02
Actual value > Upper limit SE1
03
Actual value > Lower limit SE1
04
Actual value > Upper limit SE2
05
Actual value > Lower limit SE2
06
Actual value > Upper limit SG1
07
Actual value > Lower limit SG1
08
Actual value > Upper limit SG2
09
Actual value > Lower limit SG2
10
Actual value > Upper limit SG3
11
Actual value > Lower limit SG3
12
Actual value > Upper limit SG4
13
Actual value > Lower limit SG4
16
Actual value > Upper limit SBR
17
Actual value > Lower limit SBR
See also: C01711 "SI motion: Defect in a monitoring channel".
8-298
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 03.2006 Edition
Minimum value:
Maximum value:
Checksum: