Siemens SINUMERIK 840D sl Function Manual page 115

Sinumerik safety integrated
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

03.06
Table 6-3
Overview of stop responses
STOP
Action
F
Depending on the
particular situation
a) Safety function
inactive:
Saved (latched)
message to the
operator
b) Safety function
active:
STOP B/A is initiated
(can be configured)
c) Safety function active
and STOP C, D or E
initiated:
Saved (latched)
message to the
operator
Note:
The timers can be set using the appropriate machine data.
Configurable stop responses
The stop responses that occur when limit values are violated can be selected by
the machinery construction OEM using the appropriate machine data. These limit
values are defined using the corresponding machine data:
Table 6-4
Safety-
related function
SBH
SG
SE
SN
SBR
Crosswise data comparison: STOP F cannot be configured
Note:
* There is an immediate transition from STOP B to A if t
threshold is exceeded.
© Siemens AG, 2006. All rights reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 03.2006 Edition
Safety Functions Integrated in the System/Drive
Effect
a) NC start and
traversing interlock
b) Transition to STOP
B/A
c) NC start and
traversing interlock
Configurable stop responses
Configurable stop responses
STOP B* (cannot be configured)
STOP A, B*, C, D, E
STOP C, D, E
No internal stop response
When required, the user can configure the appropriate safe
stop resonses using the SGAs SN1, SN2, ... .
STOP A (cannot be configured)
6.3 Safe stops A-F
Initiated in
Changes
response to
to
a) ––
Crosswise data
b) SH
comparison
c) ––
= 0 or the parameterized speed
B
Alarm
a) RESET
b) POWER
ON
c) RESET
6-115

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics s120

Table of Contents