Diagnostics
03.06
10.1 Troubleshooting procedure
Fig. 10-1
Status SI
The axis +, axis – vertical softkeys or direct selection are used to set the desired
axis. The active axis is displayed in the top right half of the table.
The vertical softkeys "SGE/SGA" and "SPL" can be used to select two additional
screens, which show the situation for the safety-related inputs/outputs and the safe
programmable logic.
© Siemens AG, 2006. All rights reserved
10-370
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 03.2006 Edition