2.3
Measure workpiece (milling)
2.3.1
Calibrate probe - length (CYCLE976)
Function
Using this measuring version, the length of a workpiece probe can be calibrated in the tool
axis on a known surface (reference area). This can be done, for example, on a workpiece.
Measuring principle
The probe travels in the measuring direction on the edge (e.g. workpiece)
Figure 2-8
The length of the probe is determined corresponding to the setting in general MD 51740
$MNS_MEA_FUNCTION_MASK, bit 1. The setting determines whether the tool length refers
to the probe ball center or the probe ball circumference.
In the version tool length to ball center, a trigger value is entered into the calibration data
according to the calibration direction.
References: Commissioning Manual
Chapter "Measuring cycles and measurement functions".
Preconditions
● The probe must be active as tool.
● Probe type:
Measuring cycles
Programming Manual, 02/2011, 6FC5398-4BP40-0BA0
Calibrate: Length at edge (CYCLE976)
– 3D multi probe (type 710)
– Mono probe (type 712)
– L probe (type 713)
SINUMERIK Operate (IM9) / SINUMERIK 840D sl
Measuring variants
2.3 Measure workpiece (milling)
,
83