Siemens SINUMERIK 840D sl Programming Manual page 24

Measuring cycles
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Description
1.7 Probe, calibration body, calibration tool
Calibration, calibration tool
A probe must be calibrated before it can be used. Calibration involves precisely determining
the triggering points (switching points) of the tool probe and entering them in special data
fields.
Calibration is performed with a calibration tool. The precise dimensions of the tool are
known.
Use the same measuring velocity for calibrating and measuring.
Measurement version Calibrate probe (CYCLE971) (Page 202) is ready for calibration.
Entry in tool memory
Tool type ($TC_DP1[ ]):
Length 1 - geometry
($TC_DP3[ ]):
Radius ($TC_DP6[ ]):
Length 1 - basic dimension
($TC_DP21[ ]):
The wear and other tool parameters must be assigned the value 0.
24
Calibrating tool probes
1xy
L1
r
only if required
Programming Manual, 02/2011, 6FC5398-4BP40-0BA0
Measuring cycles