Measuring variants
2.5 Measure tool (milling)
Figure 2-35
Preconditions
Note
The tool probe must be calibrated before the tool measurement (see Calibrate probe
(CYCLE971) (Page 202)).
● The tool geometry data (approximate values) must be entered in a tool offset data set.
● The tool must be active.
● The machining plane must be programmed in which the probe was calibrated.
● The tool must be prepositioned in such as way that collision-free approach with the probe
Starting position before the measurement
Before the cycle call, a starting position must be assumed from which the probe can be
approached collision-free. The measuring cycle calculates the direction of approach and
generates the appropriate traversing blocks.
Figure 2-36
210
Radius measurement with and without offset
is possible in the measuring cycle.
1
Calibrate probe (CYCLE971), starting positions for calibration in the plane
General SD 54626 $SNS_MEA_TP_TRIG_PLUS_DIR_AX1
General SD 54625 $SNS_MEA_TP_TRIG_MINUS_DIR_AX1
2
Programming Manual, 02/2011, 6FC5398-4BP40-0BA0