Measuring cycles
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Calibration, gauging block
Figure 1-5
A probe must be calibrated before it can be used. When being calibrated, the trigger points
(switching points), position deviation (skew), and precise ball radius of the workpiece probe
are determined and entered into the corresponding data fields of the general setting data
SD 54600 $SNS_MEA_WP_BALL_DIAM .
The default setting has data fields for 12 probes.
Calibration of the workpiece probe on turning machines is usually performed with gauging
blocks (reference grooves). The precise dimensions of the reference groove are known and
entered in the associated data fields of the following general setting data:
● SD54615 $SNS_MEA_CAL_EDGE_BASE_AX1
● SD54616 $SNS_MEA_CAL_EDGE_UPPER_AX1
● SD54617 $SNS_MEA_CAL_EDGE_PLUS_DIR_AX1
● SD54618 $SNS_MEA_CAL_EDGE_MINUS_DIR_AX1
● SD54619 $SNS_MEA_CAL_EDGE_BASE_AX2
● SD54620 $SNS_MEA_CAL_EDGE_UPPER_AX2
● SD54621 $SNS_MEA_CAL_EDGE_PLUS_DIR_AX2
● SD54622 $SNS_MEA_CAL_EDGE_MINUS_DIR_AX2
The default setting has data fields for three gauging blocks. In the measuring cycle program,
the selection is made using the number of the gauging block (S_CALNUM).
It is also possible to calibrate on a known surface.
Measuring cycle CYCLE973 with various measuring versions is ready for calibration.
See also
Calibrate probe - length (CYCLE973) (Page 57)
Calibrate probe - radius on surface (CYCLE973) (Page 60)
Calibrate probe - calibrate in groove (CYCLE973) (Page 63)
Measuring cycles
Programming Manual, 02/2011, 6FC5398-4BP40-0BA0
Calibrating a workpiece probe, example: Calibrating in the reference groove
1.7 Probe, calibration body, calibration tool
Description
27