CAUTION!
Configuration hazard – risk of data corruption. Maintenance mode is provided for troubleshooting
purposes and should only be used by Siemens Canada Ltd. technicians. As such, this mode is not fully
documented. Misuse of this maintenance mode commands can corrupt the operational state of the
device and render it inaccessible.
NOTE
The maintenance password/passphrase must be reset on both partitions.
To reset the maintenance password/passphrase, do the following:
1.
Make sure the CLI is in Configuration mode.
2.
Reset the maintenance password by setting a new password. For more information, refer to
"Setting the Maintenance
3.
Reboot the device. For more information, refer to
4.
As soon as the device starts to boot up, press ESC. A list of possible boot modes for each partition appears.
****Boot Partition 4****
[4-0]: Debian GNU/Linux, kernel 3.0.0-2-8360e
[4-1]: Debian GNU/Linux, kernel 3.0.0-2-8360e (BIST mode)
[4-2]: Debian GNU/Linux, kernel 3.0.0-2-8360e (single-user mode)
[4-3]: Debian GNU/Linux, kernel 3.0.0-2-8360e (service mode)
****Boot Partition 6****
[6-0]: Debian GNU/Linux, kernel 3.0.0-2-8360e
[6-1]: Debian GNU/Linux, kernel 3.0.0-2-8360e (BIST mode)
[6-2]: Debian GNU/Linux, kernel 3.0.0-2-8360e (single-user mode)
[6-3]: Debian GNU/Linux, kernel 3.0.0-2-8360e (service mode)
Auto booting [4-0], Hit [ESC] key to stop:
Welcome to the boot menu. Please select from the following options:
Enter [BootPartition-BootTarget] (e.g. '4.0') to boot.
'h' Show this help menu
'l' List the available boot targets
'c' Exit to the boot loader command line
Will reboot after 60 seconds of inactivity
:
NOTE
In the example above, the text Auto booting [4-0] indicates the active partition is Boot
Partition 4.
5.
Enter the inactive partition by typing the associated target number. For example, if the active partition is Boot
Partition 4, type 6-0 and press Enter to enter Boot Partition 6.
6.
Log in to RUGGEDCOM ROX II. For more information about logging in to RUGGEDCOM ROX II, refer to
Section 2.3, "Logging
7.
Repeat
Step 1
original partition.
Resetting the Maintenance Password/Passphrase
Password/Passphrase".
In".
and
Step 5
to reset the password/passphrase on the inactive partition and switch back to the
Section 3.5, "Rebooting the