Configuring a Switched Ethernet Port

To configure a switched Ethernet port, do the following:
1.
Make sure the CLI is in Configuration mode.
2.
Navigate to interface » switch » {slot} » {port}, where {slot} is the module and {port} is the switched
Ethernet port.
3.
Configure the port settings by configuring the following parameter(s) as required:
CAUTION!
Security hazard – risk of unauthorized access and/or exploitation. Switched Ethernet ports are
enabled by default. It is recommended that ports that are not in use be disabled. Unused ports, if
not configured properly, could potentially be used to gain access to the network behind the device.
CAUTION!
Configuration hazard – risk of data corruption. Changing a switched Ethernet port from switchport
mode to dedicated routing mode will automatically change any configuration elements that
depended on it and potentially invalidate parts of the device configuration. For example, if a
switched Ethernet port is a trunk port, changing it to dedicated routing mode will automatically
remove it from the trunk and, therefore, make the trunk invalid. A trunk must consist of two trunk
ports.