Toshiba TOSVERT VF-S9 Instruction Manual page 69

Compact inverter 1-phase 200v class 0.2 2.2kw 3-phase 200v class 0.2 15kw 3-phase 400v class 0.75 15kw
Hide thumbs Also See for TOSVERT VF-S9:
Table of Contents

Advertisement

Adjustment scale with meter adjustment
Connect meters as shown below.
<Frequency meter>
Optional frequency meter: QS-60T
[Connected meter selection parameters]
Title
Function
Meter selection
Meter adjustment
Resolution
All FM terminals have a maximum of 1/256
Example of 4-20mA programmed output (for details, see 6.15.10)
parameter
<Ammeter>
Meter: frequency meter
(default setting)
The reading of the
frequency meter
will fluctuate during
scale adjustment.
Make the maximum ammeter scale at least 150
percent of the inverter's rated output current
Adjustment range
0: Output frequency
1: Output current
2: Set frequency
3: For adjustment (current fixed at 100%)
4: Inverter load factor
5: Output power
-
E-9
E6580757
Meter: ammeter
(
The reading of the
frequency meter
will fluctuate during
scale adjustment.
Default setting
0
-
Set the
if adjusting the bias.
= 1)
5