(11) Switching between analog setting and
preset-speed setting
Current
signal
Voltage signal
To switch to preset-speed setting,
use the external terminals S1 to S4.
(13) Setting by means of a remote input device
7
Priority is given to the remote input device
when the remote command fa00h 14-bit is
set at 1.
F
R
RST
STOP
RUN
S1
S2
S3
CC
PP
VB
I I
VIA
CC
F
R
RST
STOP
RUN
S1
S2
S3
CC
PP
VIB
I I
VIA
CC
Serial I/F
(12) Switching between analog setting and terminal set-
ting from the operation panel
Current
signal
Voltage signal
To switch to VIA/II or VIB setting, use the ex-
ternal PNL/TB.
(14) Switching between remote control and local control
Remote control can be switched forcefully to
local control from the external SC/LC by setting
the remote command fa00h 14-bit at 1.
The operation is controlled in accordance with
the
G-4
E6580757
F
R
RST(PNL/T
STOP
RUN
S1
S2
S3
CC
PP
VIB
I I
VIA
CC
F
R
RST
STOP
RUN
S1(SC/LC)
S2
S3
CC
PP
VIB
I I
VIA
CC
Serial I/F
setting.