Installation Location - Toshiba TOSVERT VF-S9 Instruction Manual

Compact inverter 1-phase 200v class 0.2 2.2kw 3-phase 200v class 0.2 15kw 3-phase 400v class 0.75 15kw
Hide thumbs Also See for TOSVERT VF-S9:
Table of Contents

Advertisement

How to install
• Do not install and operate the inverter if it is damaged or any component is missing.
Prohibited
• Must be installed in nonflammables such as metals.
1
• Do not operate with the front panel cover removed. This can result in electric shock.
• An emergency stop device must be installed that fits with system specifications (e.g. cuts off input
Mandatory
• All options used must be those specified by Toshiba. The use of any other option may result in an acci-
• The main unit must be installed on a base that can bear the unit's weight.
• If braking is necessary (to hold motor shaft), install a mechanical brake. The brake on the inverter will
Mandatory

Installation location

Select a location with good indoor ventilation, place lengthwise in the vertical direction and attach to a metal
wall surface.
If you are installing more than one inverter, the separation between inverters should be at least 5 centime-
ters, and they should be arranged in horizontal rows.
If the inverters are horizontally arranged with no space between them (side-by-side installation), peel of the
ventilation seals on top of the inverters and operate at 40°C or less (model of 3.7kW or less). Operate at
50°C or less (model of 5.5kW or more).
• • • •
Standard installation
5 centimeters
or more
The space shown in the diagram is the minimum allowable space. Because air cooled equipment has cooling
fans built in on the top or bottom surfaces, make the space on top and bottom as large as possible to allow
for air passage.
This can result in electric shock or fire. Please consult your local agency for repairs.
The rear panel gets very hot so that if installation is in an inflammable object, this can result in fire.
power then engages mechanical brakes).
Operation cannot be stopped immediately by the inverter alone, thus risking an accident or injury.
dent.
If the unit is installed on a base that cannot withstand that weight, the unit may fall resulting in injury.
not function as a mechanical hold, and if used for that purpose, injury may result.
10 centimeters
or more
VFS9
5 centimeters
or more
10 centimeters
or more
Danger
Warning
• • • •
Horizontal installation (side-by-side installation)
VFS9
VFS9
VFS9
Ambient temperature of 40°C or less (model of 3.7kW or less)
Ambient temperature of 50°C or less (model of 5.5kW or more).
A-18
E6580757
10 centimeters or
more
Remove seals on
top

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents