Terminal
Input/output
symbol
Multifunction programmable open collector
output. Standard default settings detect
OUT
Output
and output speed reach signal output fre-
quencies.
Multifunction programmable relay contact
output. Contact ratings: 250Vac -2A (cosφ
RC
Output
= 1), 30Vdc-1A, 250Vac-1A (cosφ = 0.4).
RY
Standard default settings detect and out-
put low-speed signal output frequencies.
Multifunction programmable relay contact
output. Contact ratings: 250Vac -2A (cosφ
FLA
= 1), 30Vdc-1A, 250Vac-1A (cosφ = 0.4).
FLB
Output
Detects the operation of the inverter's
FLC
protection function. Contact across FLA-
FLC is closed and FLB-FLC is opened
during protection function operation.
Function
Open collector out-
put : 24Vdc-50mA
*Sink-source
switchable
(JP301A)
250Vac-2A (cosφ =
1)
: at resistance load
30Vdc-1A
: 250Vac-1A (cosφ
= 0.4)
250Vac-2A (cosφ =
1)
: at resistance load
30Vdc-1A
: 250Vac-1A (cosφ
= 0.4)
B-9
Electrical
Inverter internal circuits
specifications
SOURCE
24V
OUT
FUSE
10
RC
RY
FLA
FLB
FLC
E6580757
JP301
5V
150
10
150
2
+24V
RY
+24V
RY