428 The Safe torque off function
Term or
Reference
abbreviation
PFH
IEC 61508
PFH diag
IEC/EN 62061
PL
EN ISO 13849-1
Proof test
IEC 61508, IEC
62061
SC
IEC 61508
SFF
IEC 61508
SIL
IEC 61508
STO
IEC/EN 61800-5-2
T 1
IEC 61508-6
T M
EN ISO 13849-1
λ Diag_d
IEC 61508-6
λ Diag_s
IEC 61508-6
TÜV certificate
The TÜV certificate is available on the Internet at www.abb.com/drives/documents.
Description
Average frequency of dangerous failures per hour, that
is, average frequency of a dangerous failure of a safety
related system to perform the specified safety function
over a given period of time
Average frequency of dangerous failures per hour for the
diagnostic function of STO
Performance level. Levels a...e correspond to SIL
Periodic test performed to detect failures in a
safety-related system so that, if necessary, a repair can
restore the system to an "as new" condition or as close
as practical to this condition
Systematic capability (1...3)
Safe failure fraction (%)
Safety integrity level (1...3)
Safe torque off
Proof test interval. T 1 is a parameter used to define the
probabilistic failure rate (PFH or PFD) for the safety
function or subsystem. Performing a proof test at a
maximum interval of T 1 is required to keep the SIL
capability valid. The same interval must be followed to
keep the PL capability (EN ISO 13849) valid.
See also section Maintenance.
Mission time: the period of time covering the intended
use of the safety function/device. After the mission time
elapses, the safety device must be replaced. Note that
any T M values given cannot be regarded as a guarantee
or warranty.
Dangerous failure rate (per hour) of the diagnostics
function of STO
Safe failure rate (per hour) of the diagnostics function
of STO