Impact on the System
The faulty button cannot be used.
Preparations
Procedure
Step 1 Remove the button.
1.
2.
3.
Figure 6-21 Removing the button
Step 2 Use the nut furnished with the new button to secure the button to the post and connect the
cable to the button.
Step 3 Verify that the button function is normal.
Step 4 Reinstall the post side panel.
----End
Issue 05 (2020-03-25)
Tool: socket wrench
Material: door open button, emergency button, or light button
Lift the side panel of the door post.
Remove the side panel of the door post outwards.
Remove the button connection cable, the nut on the button installation position, and then
the button.