Figure 21
1. Nut
2. Bolt
3. Right side
10.
Drain half of the engine coolant from the radiator
by using the valve on the right side of the
radiator as shown in
11.
Locate and remove the engine plugs shown in
Figure
20.
12.
Apply pipe sealant to the threads on the engine
fittings.
13.
Manually secure the engine fittings into the ports
until they are finger-tight.
14.
Secure the engine fittings 2 to 3 additional turns
from finger-tight.
15.
Slip the hose clamps over the hoses.
16.
Insert the hoses over the barb ends of the
engine fittings and secure them with the hose
clamps
(Figure
20).
17.
Install the R-clamps around the hoses
20).
18.
Secure the hoses to the back of the cab with 2
carriage bolts and 2 nuts
22).
4. Existing bracket
5. Radiator valve
Figure
21.
(Figure
(Figure 20
and
Figure
g315428
1. Direction of fluid flow
2. Couplers installed
3. R-clamp
4. Cable tie
19.
Secure the hoses away from moving parts and
hot surfaces with cable ties.
20.
Fill the radiator with engine coolant.
21.
Start the engine and purge the air out of the
cooling system.
22.
Shut off the engine and check the engine-coolant
level.
23.
If needed, add more engine coolant.
Note:
When the engine is cold, the coolant
level should be no higher than the FULL (COLD)
mark (bottom mark).
Note:
Refer the traction unit Operator's Manual
for the correct fluid.
15
Figure 22
5. Nut (1/4 inch)
6. Carriage bolt (1/4 x 3/4
inch)
7. Tag—noting hot line
g301828