7.3 Data Compatibility with MELDASMAGIC50

USERPLC.LAD and data (parameters and so on) other than machining programs, created by
MAGIC50, cannot be used by MAGIC64.
The ladder program files (USERPLC.LAD) created by MAGIC50 can be converted into the ladder
program file for MAGIC64 using the cnv4bmm.exe and chgcx.exe tools. (Refer to operarion of 1) and
2) in the figure below.)
The machining program files created by MAGIC50 can be used directly by MAGIC64.
MAGIC64
Backup applicable O
Downloaded from
ManualsNet.com
7.3 Data Compatibility with MELDASMAGIC50
File transfer
utility
Files output from PLC4B are
converted directly by chgcx.
Not available
Caution
Since files other than USERPLC.LAD or machining programs
are not compatible with MAGIC50, files output by MAGIC50
cannot be used.
search engine
7. Appendices
cnv4bmm and chgcx are DOS applications.
They are packaged with the ladder creation tool.
Refer to the manual of the ladder creation tool for the
usage of chgcx.
2) chgcx LAD1 LAD2
1) cnv4bmm -4 USERPLC.LAD LAD1
USERPLC.LAD
M01:\LAD\USERPLC.LAD is
copied to the personal computer
side on the file transfer window.
********.PRG(machining program)
Files other than above
ALL.PRM
PARAMET.BIN
FILESYS.BIN
RREG.BIN
TREG.BIN
CREG.BIN
MAGIC64 data can be saved (backed
up) in the personal computer.
89
MAGIC50
MMI
WORK.OFS
TOOL.OFS
USERPLC.LAD
********.PRG