Connecting Rod Installation (continued)
Compression System: Service and Repairs
2. Install the connecting rod cap.
3. Install the 2 (10 mm) connecting rod cap bolts. Torque bolts to 108–132
in-lbs. (13–15 Nm).
Figure 179
Figure 180
Page 7–38
1P65F-2 Service Manual