7.6 Device Range that Can Be Set
The device ranges of controller that can be used for GOT
are as follows.
Note that the device ranges in the following tables are the
maximum values that can be set in GT Designer3.
The device specifications of controllers may differ
depending on the models, even though belonging to the
same series.
Please make the setting according to the specifications of
the controller actually used.
When a non-existent device or a device number outside
the range is set, other objects with correct device settings
may not be monitored.
Setting item
Item
Set the device name, device number, and bit number.
Device
The bit number can be set only when specifying the bit of
word device.
Displays the device type and setting range which are
Information
selected in [Device].
Set the monitor target of the set device.
Network
Station
Select this item when monitoring the PLC of the
No.
specified station No.
Description
7.6.1
KOYO EI PLC
(KOYO KOSTAC/DL)
Device name
*5
Input (I)
*5
Output (Q)
Link relay (GI)
Link output (GQ)
Internal relay (M)
Stage (S)
Timer (T)
Counter (C)
*1
Special relay (SP)
Timer (current value) (R)
*5
Preparatory register (R)
*1*5
Special register 1 (R)
*3
Timer (current value) (R)
*2*5
Data register 1 (R)
*1*4*5
Special register 2 (R)
*5
Data register 2 (R)
*1*5
Special register 3 (R)
Link relay (R)
Link output (R)
Input (R)
Output (R)
Internal relay (R)
Stage (R)
Timer (R)
Counter (R)
Special relay (R)
*1
Read-only device for KOSTAC SU series
*2
The GOT cannot write data to R7377 for the SU-5M and SU-
6M.
*3
For Direct Logic 05 series and Direct Logic 06 series,
devices from R1200 to R1377 are used as V-memory 2.
*4
The GOT cannot write data to devices from R7766 to R7774
(calendar area).
*5
The device names differ according to the series.
The following shows the device names for each series.
KOSTAC SU
Direct Logic 05
PZ
Direct Logic 06
Input
Input relay
Output
Output relay
Preparatory
V-memory 1
register
Special register 1
System parameter 1
Data register 1
V-memory 2
Special register 2
System parameter 2
Data register 2
V-memory 3
Special register 3
System parameter 4
7. CONNECTION TO KOYO EI PLC
7.6 Device Range that Can Be Set
Device
No.
Setting range
represent
ation
I0 to I1777
Q0 to Q1777
GI0 to GI3777
GQ0 to GQ3777
M0 to M3777
S0 to S1777
T0 to T377
C0 to C377
SP0 to SP777
R0 to R377
R400 to R677
R700 to R777
R1000 to R1377
Octal
R1400 to R7377
R7400 to R7777
R10000 to R36777
R37000 to R37777
R40000 to R40177
R40200 to R40377
R40400 to R40477
R40500 to R40577
R40600 to R40777
R41000 to R41077
R41100 to R41117
R41140 to R41157
R41200 to R41237
Direct Logic 205
Input
Output
Data register 1
System parameter 1
Data register 2
System parameter 2
Data register 3
System parameter 4
7 - 27
1
2
3
4
5
6
7
8