Mitsubishi Electric GOT1000 Series Connection Manual page 142

Graphic operation terminal
Hide thumbs Also See for GOT1000 Series:
Table of Contents

Advertisement

RS485 connection diagram 8)
* 3
GOT side
SDA
1
SDB
6
RDA
2
RDB
7
SG
5
RSA
3
CSA
4
RSB
8
CSB
9
FG
-
*1
Pin No. of control equipment differs depending on model or optional function model.
Refer to the following table. The numbers in ( ) of the following table correspond to optional function models.
Signal name
RDA
RDB
SDA
SDB
SG
FG
Signal name
RDA
RDB
SDA
SDB
SG
FG
*2
Terminating resistor should be provided for a control equipment which will be a terminal.
*3
Set the terminating resistor of GOT as follows.
GT16, GT15, GT12: Set the terminating resistor setting switch of the GOT main unit to "100 OHM".
GT14, GT11: Set the terminating resistor selector to "330 ".
*4
Connect FG grounding to the single-sided end of a cable shield line.
3 - 28
3. CONNECTION TO AZBIL CONTROL EQUIPMENT
3.3 Connection Diagram
Control equipment
side
* 1
RDA
RDB
SDA
SDB
SG
FG
* 4
Terminating resistor(150Ω 1/2W)
SDC20
SDC21
(02, 04)
(09)
(03, 06, 08)
Pin No.
Pin No.
Pin No.
17
18
27
18
19
28
15
16
25
16
17
26
5
5
3, 4
3, 4
3, 4
CMF050
PBC201-VN2
CML
Pin No.
Pin No.
7
8
9
10
12
19
■ Connecting terminating resistors
* 4
* 2
Model of control equipment
SDC30
(040, 041)
(045)
Pin No.
Pin No.
18
18
19
19
16
16
17
17
29
5
5
3, 4
3, 4
Model of control equipment
CMC10B
Pin No.
14
13
15
14
12
11
13
12
16
15
3
-
Control
equipment
side
* 1
RDA
RDB
SDA
SDB
SG
FG
SDC31
SDC40A/40B/40G
(446, 546)
Pin No.
Pin No.
27
59
28
60
25
57
26
58
29
61
3, 4
3
AHC2001
SCU module
Pin No.
3
2
5
4
1
-

Advertisement

Table of Contents
loading

Table of Contents