Document Revision 1
20-11-18 : Class of Service Options (Hold/Transfer Service) - Transfer Recall On Receiving COS
Allow (0) or deny (1) unanswered Transferred calls to the COS from recalling the originating
extension.
For example, with this option set to '1' for COS 1, calls transferred by any COS to any extension with

a COS of 1, will not recall.
20-11-20
Class of Service Options (Hold/Transfer Service) - Transfer Recall On Originating COS
Allow (0) or deny (1) unanswered Transferred calls from the COS from recalling the originating
extension.
For example, with this option set to '1' for COS 1, any call transferred by an extension with COS 1,

will not recall.
20-13-10
Class of Service Options (Supplementary Service) - Barge-In Mode
In an extension's Class of Service, enable the Barge-In Speech Mode (0) at the initiating
extension (i.e., Barge-In initiator). This is required in order to transfer a call into a conference.
20-13-15
Class of Service Options (Supplementary Service) - Barge-In Initiate
In an extension's COS, enable (1) or disable (0) the extension's ability to Barge-In to a call.
20-13-16
Class of Service Options (Supplementary Service) - Barge-In Receive
In an extension's COS, enable (1) or disable (0) the extension's ability to receive a Barge-In on a
call.
20-13-17
Class of Service Options (Supplementary Service) - Barge-In Tone/Display
Enable (1) or disable (0) the Barge-In Tone. If disabled, this also turns off the Barge-In display at
the called extension. As this option is for extensions and trunks do not have an option for a
Barge-In Tone, the tone will be sent to the trunks based on the Class of Service of the
transferring extension.
20-13-32
Class of Service Options (Supplementary Service) - Multiple Barge-In
Enable (1) or disable (0) the extension's ability to have multiple user's Barge-In to their
conversation.
20-14-11
Class of Service Options For DISA/E&M - DISA/Tie Trunk Barge-In
Determine if DISA and tie trunk users should have the ability to dial a service code to Barge-In to
a conference call.
0 = Disabled
1 = Enabled
20-18-07
Service Tone Timer - Intrusion Tone Repeat Time
After a user Barges In, the system repeats the Barge-In tone after this interval. Normally, you
should disable this timer by entering 0. (This timer also affect any other types of call interruption
features, such as Voice Mail Conversation Recording, Voice Over, etc.)
21-01-03
System Options for Outgoing Calls - Trunk Interdigit Time (External)
Program how long an extension must wait before using the Barge-In feature can be used on a
call (this timer waits until this timer expires before putting a call in a talk state). This timer also
affects Voice Over.