Document Revision 1
12-01-01
Night Mode Function Setup - Manual Night Service Enable
Allow (1) or prevent (0) any extensions from activating Manual Night Service.
12-01-02
Night Mode Function Setup - Automatic Night Service Enabled
Enable (1) or disable (0) Automatic Night Service for the system. Make sure to set the Service
Patterns in 12-02-01, 12-02-02 and 12-02-03.
12-02-01
Automatic Night Service Patterns - Start Time
For each Night Service Group, enter up to 20 start times for each Time Pattern (1~10).
The pattern's first start time (Pattern 1) should begin at 00:00 (midnight).
12-02-02
Automatic Night Service Patterns - End Time
For each Night Service Group (01~32), enter up to 20 end times (0000~2359) for each Time
Pattern (1~10).
12-02-03
Automatic Night Service Patterns - Operation Mode
For each Night Service Group (01~32), define the Night Service Mode (1~8) for up to 20 start/
end times for each Time Pattern (1~10).
12-03-01
Weekly Night Service Switching
Assign one of the 10 Time Patterns programmed in 12-02-01 to each day of the week.
12-04-01
Holiday Night Service Switching
Assign one of the 10 Time Patterns to holidays.
12-05-01
Night Mode Group Assignment for Extensions
Assign a Day/Night Mode Group (01~32), for each extension.
12-06-01
Night Mode Group Assignment for Trunks
Assign a Day/Night Mode Group (01~32), for each trunk port (1~200).
12-07-01
Text Data for Night Mode
Create an original text message which will be displayed on an LCD of multiline terminal in each
Night Mode.
12-08-01
Night Mode Service Range
For each Night Mode Group (01~32), determine how many night modes a user will toggle
through when the Night Mode key is pressed.
14-07-01
Trunk Access Map Setup
To allow for UNA answering, set up the Trunk Access Maps (1~200). For UNA, extension must
have incoming access to trunk ringing the External Paging speakers.
15-06-01
Trunk Access Map for Extensions
For UNA answering, assign Trunk Access Maps (1~200) to extensions. Make one entry for each
Night Service mode.
2 - 620