Document Revision 1
20-28-01
System Option Setup - Conversation Continue Code
When Program 14-01-25 is enabled, determine the 1-digit code the user should dial (0~9,
to extend the conversation length for the time defined in 20-28-03. If the Continue and
Disconnect codes are programmed the same (e.g., #), the system will follow the "Continue"
operation. Using the Continue code before the warning tone is heard has no action.
20-28-02
System Option Setup - Conversation Disconnect Code
When Program 14-01-25 is enabled, determine the 1-digit code the user should dial (0~9,
to immediately disconnect their call. Using the Disconnect code before the warning tone is heard
will disconnect the call.
20-28-03
System Option Setup - Conversation Extend Time
When Program 14-01-25 is enabled, determine the length of time a call will be extended
(0~64800 seconds) when the user dials the Continue code (defined in 20-28-01).
24-02-07
System Options for Transfer - Trunk-to-Trunk Transfer Release Warning Tone
This timer will start when a trunk begins talking with another trunk (for example: trunk-to-trunk
transfer/Tandem Trunking). When this timer expires, a warning tone is heard. If Program
24-02-10 is set, the conversation disconnects after that timer expires. This timer is set again
when the external digit timer expires. One of the trunks used must be an analog trunk (or leased
line). Entries: 0~64800 (seconds).
This applies to manually transferred Tandem Trunk and DISA calls.

24-02-10
System Options for Transfer - Trunk-to-Trunk Transfer Disconnect Timer
Determine how long a conversation will continue (0~64800 seconds) once the timer in Program
24-02-07 expires. If this option is set to "0", the conversation will be disconnected immediately.
This program has no affect if Program 24-02-07 is set to "0". One of the trunks used must be an
analog trunk (or leased line).
This applies to manually transferred Tandem Trunk and DISA calls.

25-07-07
System Timers for VRS/DISA - DISA Long Conversation Warning Tone Time
Determine the length of time a DISA caller can talk before the Long Conversation tone is heard
(0~64800 seconds). If Program 25-07-08 is set to "0", the call is disconnected once the timer
expires. This timer is set again when the external digit timer expires.
This applies to automatically transferred Tandem Trunk and DISA calls.

25-07-08
System Timers for VRS/DISA - DISA Long Conversation Disconnect Timer
This timer determines how long the system will wait (0~64800 seconds) before disconnecting a
DISA call after the Long Conversation tone is heard. This program has no affect if Program
25-07-07 is set to "0".
This applies to automatically transferred Tandem Trunk and DISA calls.