20-06-01
Class of Service for Extensions
Assign a Class of Service (1~15) to an extension.
20-07-11
Class of Service Options (Administrator Level) - Forced Trunk Disconnect
In an extension's Class of Service, enter 1 to enable Forced Trunk Disconnect. This allows the
extension to disconnect an Unsupervised Conference in progress (initially set up using Method
B).
20-11-14
Class of Service Options (Hold/Transfer Service) - Trunk-to-Trunk Transfer
Disable (0) the Trunk-to-Trunk Transfer Restriction option.
20-11-21
Class of Service Options (Hold/Transfer Service) - Restriction for Tandem Trunking on
Hang Up
Deny (1) an extension user's ability to set up a tandem call automatically when they hang up.
20-13-10
Class of Service Options (Supplementary Service) - Barge-In Mode
In an extension's Class of Service, set whether an extension should be able to Barge-In to a call
and talk (1) or just monitor the call (0).
24-02-07
System Options for Transfer - Trunk-to-Trunk Transfer Release Warning Toner
This timer will start when a trunk begins talking with another trunk (for example: trunk-to-trunk
transfer, outgoing from trunk, Tandem Trunking) (0~64800 seconds).
24-02-10
System Options for Transfer - Trunk to Trunk Transfer Disconnect Time
This timer will start after the Trunk to Trunk warning tone is heard.(0-64800 seconds).
25-07-07
System Timers for VRS/DISA - DISA/Tandem Trunking Long Conversation Warning Tone
Time
Determine the length of time a DISA caller or any trunk-to-trunk (such as Tandem Trunking)
conversation can talk before the Long Conversation tone is heard (0~64800 seconds).
25-07-08
System Timers for VRS/DISA - DISA/Tandem Trunking Long Conversation Disconnect
This timer determines how long the system will wait before disconnecting a DISA or any
trunk-to-trunk (such as Tandem Trunking) call after the Long Conversation tone is heard
(0~64800 seconds).
Tandem Trunking Method C - Tandem Trunking on Hang up
10-07-01
Conversation Record Circuits
The number of circuits assigned as Conversation Record circuits limits the number of available
Conference circuits. Make sure there are circuits available for the conference.
14-01-04
Basic Trunk Data Setup - Transmit Gain Level for Conference and Transfer Calls
Select the CODEC gain type used by the trunk when it is part of an Unsupervised Conference.
14-01-05
Basic Trunk Data Setup - Receive Gain Level for Conference and Transfer Calls
Select the CODEC gain type used by the trunk when it is part of an Unsupervised Conference.