Safety Data For Power Modules, Chassis Format - Siemens SINAMICS S120 Equipment Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

System overview
3.5 System data
Table 3- 4
Certificates
Declarations of Conformity
FSA-FSC approvals
Approvals FSD-FSG
3.5.2

Safety data for Power Modules, chassis format

Table 3- 5
Electrical data
Line connection voltage
Rated pulse frequency
Line system types
Line frequency
Radio interference suppression
Output voltage
Electronics power supply
Short-circuit current rating SCCR according
to UL508C (up to 600 V)
Overvoltage category
Degree of pollution
100 % output voltage only possible with modulation type "edge modulation" (FLM).
1)
When using a motor holding brake, possibly restricted voltage tolerances (24 V ±10 %) must be taken into account.
2)
Table 3- 6
Degree of protection / protection class
Degree of protection
Protection class, line supply circuits
Electronic circuits
42
CE (Low Voltage, EMC and Machinery Directives)
cULus acc. to UL 508C/CSA 22.2 No. 274
RCM (C-Tick)
SEMI F47
KCC only with internal or external line filters for Category C2
RoHS
EAC
cULus acc. to UL 508C/CSA 22.2 No. 274
RCM (C-Tick)
SEMI F47
KCC only with internal or external line filters for Category C2
WEEE (Waste Electrical & Electronic Equipment)
RoHS
EAC
3 AC 380 ... 480 V ±10 % (in operation -15 % < 1 min)
2 kHz
TN/TT line supplies or IT line supplies
47 ... 63 Hz
According to EN 61800-3
Approx. 0.95 • line voltage (maximum value)
Safety extra-low voltage (PELV) acc. to IEC 61800-5-1
Comment:
Grounding the 24 V electronics power supply
In SINAMICS S120 components, the electronics ground M is permanently
connected to the protective conductor potential.
1.1 ... 447 kW: 65 kA
UL certification applies only in conjunction with the fuses prescribed by
Siemens and not with other types or circuit breakers alone.
III to EN 61800-5-1
2 according to EN 61800-5-1
IP20 acc. to IEC 60529, open type acc. to UL/CSA
I (with protective conductor connection) according to EN 61800-5-1
protective extra low-voltage (PELV/SELV)
1)
2)
Manual, 06/2019, 6SL3097-5AL00-0BP1
AC Drive

Advertisement

Table of Contents
loading