Mounting Control Units And Control Unit Adapters - Siemens SINAMICS S120 Equipment Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

8.7

Mounting Control Units and Control Unit Adapters

Power Modules Blocksize
Control Unit (CU310-2 PN/DP) and Control Unit Adapter (CUA31/CUA32) can be mounted
onto Power Modules Blocksize of any frame size. Communication between the devices is
realized via the PM-IF interface.
Mounting
1. Mount the Control Unit / the Control Unit Adapter on the PM
Figure 8-22
2. Press the Control Unit / Control Unit Adapter back until it latches into the blue interlocking
lug
Removal
1. Press the blue locking latch downward
2. Remove the Control Unit / Control Unit Adapter towards the front.
Power Module Chassis
1. Connect the DRIVE-CLiQ interfaces of Power Module Chassis and the Control
Unit/Control Unit Adapter.
The DRIVE-CLiQ interface of the Power Module Chassis is located behind the mounting
plate.
2. Mount the Control Unit/Control Unit Adapter on the mounting plate.
AC Drive
Manual, 06/2019, 6SL3097-5AL00-0BP1
Control Units, Control Unit Adapters and operating components
Mounting (left) and removal (right) of the Control Unit
.
8.7 Mounting Control Units and Control Unit Adapters
.
.
289

Advertisement

Table of Contents
loading

Table of Contents