Initial value change list
4.23 Initial value change list
Displays and sets the parameters changed from the initial value.
Operation
1. Screen at power-ON
The monitor display appears.
2.
Press
to choose the PU operation mode.
3.
Press
to choose the parameter setting mode.
4.
Turn
until
5.
Pressing
changes to the initial value change list
screen.
6.
Turning
displays the parameter number changed.
Press
to read the currently set value.
Turn
and press
(Refer to step 6 and 7 on page 51)
Turn
to read another parameter.
The display returns to
are displayed.
7.
Pressing
in
parameter setting mode.
Turning
Pressing
NOTE
Calibration parameters (C0 (Pr.900) to C7 (Pr.905) are not displayed even they are changed from the initial settings.
Only simple mode parameter is displayed when simple mode is set (Pr.160 = 9999)
Pr.160 is displayed independently of whether the setting value is changed or not.
When parameter setting is changed after creating the initial value change list, the setting will be reflected to the initial
value change list next time.
Parameters referred to
C0(Pr.900) FM terminal calibration
C2(Pr.902) to C7(Pr.905) (Bias and gain of built-in frequency setting potentiometer)
262
appears.
to change the setting.
after all parameters
status returns to the
sets other parameters.
displays the change list again.
Refer to page 162
PU indicator is ON.
PRM indicator is ON.
(The parameter number read previously appears.)
It may take several seconds for
Flicker... Parameter setting complete!!
Refer to page 173
Display
creating the initial value change list.
"
" flickers while creating the
list.