Mitsubishi Electric FR-E700EX Instruction Manual page 235

Sensorless servo drive unit, applied
Hide thumbs Also See for FR-E700EX:
Table of Contents

Advertisement

 Faults history
Register
40501
Fault history 1
40502
Fault history 2
40503
Fault history 3
40504
Fault history 4
40505
Fault history 5
40506
Fault history 6
40507
Fault history 7
40508
Fault history 8
Data
Definition
No fault
H00
present
H10
E.OC1
H11
E.OC2
H12
E.OC3
H20
E.OV1
H21
E.OV2
H22
E.OV3
H30
E.THT
H31
E.THM
 Refer to page 267 for details of fault description.
 Model information monitor
Register
44001 to 44010
44011 to 44013
(7)
Pr.343 Communication error count
You can check the cumulative number of communication errors.
Parameter
Setting Range
343
(Reading only)
NOTE
The number of communication errors is temporarily stored into the RAM. As it is not stored into the EEPROM
performing a power supply reset or drive unit reset clears the value to 0.
(8)
Output terminal LF "alarm output (communication error warnings)"
During a communication error, the alarm signal (LF signal) is output by open collector output. Assign the used terminal
using any of Pr.190 to Pr.192 (output terminal function selection).
Master
Alarm data
Slave
Communication
0
Error count
(Pr.343)
OFF
LF signal
NOTE
The LF signal can be assigned to the output terminal using any of Pr.190 to Pr.192. Changing the terminal assignment
may affect the other functions. Set parameters after confirming the function of each terminal.
Definition
Fault code list
Data
Definition
H40
E.FIN
H52
E.ILF
H60
E.OLT
H61
E.SOT
H70
E.BE
H80
E.GF
H81
E.LF
H90
E.OHT
HA0
E.OPT
HA1
E.OP1
Definition
Read/Write
Drive unit
Read
model
Capacity
Read
Minimum Setting Range
Alarm data
Normal data
Not increased
ON
Communication error count is increased
in synchronization with leading edge
of LF signal
Communication operation and setting
Read/Write
Read/Write
Read
Being 2 bytes in length, the data is stored as "H00".
Read
Refer to the lowest 1 byte for the error code.
Read
Performing write using the register 40501 batch-clears
Read
the faults history.
Read
Set any value as data.
Read
Read
Data
Definition
HB0
E.PE
HB1
E.PUE
HB2
E.RET
HB3
E.PE2
HC0
E.CPU
HC5
E.IOH
HC7
E.AIE
HC8
E.USB
HC9
E.SAF
HD0
E.OS
Remarks
Reading drive unit model in ASCII code.
"H20" (blank code) is set for blank area
Example of FR-E720EX
H46, H52, H2D, H45, H37, H32, H30, H45, H58, H20 ...... H20
Reading drive unit capacity in ASCII code.
Data is read in increments of 0.1kW, and rounds down to
0.01kW increments
"H20" (blank code) is set for blank area
Example
0.75K................"
7" (H20, H20, H20, H20, H20, H37)
Initial Value
1
Alarm data
Reply data
1
OFF
Turns OFF when normal data is received
Alarm data: Data resulting in communication error.
Remarks
Data
Definition
HD1
E.OSD
HD3
E.OD
HDD
E.OA
HF1
E.1
HF5
E.5
HF6
E.6
HF7
E.7
HFD
E.13
0
Normal data
Reply data
2
OFF
ON
4
233