Mitsubishi Electric FR-E700EX Instruction Manual page 212

Sensorless servo drive unit, applied
Hide thumbs Also See for FR-E700EX:
Table of Contents

Advertisement

Communication operation and setting
(3) Communication operation presence/absence and data format types
 Data communication between the computer and drive unit is made in ASCII code (hexadecimal code).
 Communication operation presence/absence and data format types are as follows:
No.
Operation
Communication request is sent to the
1)
drive unit in accordance with the user
program in the computer.
2)
Drive unit data processing time
Reply data from the
3)
drive unit (Data 1) is
checked for error)
4)
Computer processing delay time
Answer from
computer in response
5)
to reply data 3).
(Data 3) is checked
for error)

In the communication request data from the computer to the drive unit, 10ms or more is also required after "no data error (ACK)". (Refer to page 212)

Reply from the drive unit to the drive unit reset request can be selected. (Refer to page 216)

When any of "0.01 to 9998" is set in Pr.37 and "01" in instruction code HFF sets data format to A2 or E2. In addition, data format is always A2 and E2
for read or write of Pr.37.

At mode error, and data range error, C1 data contains an error code. (Refer to page 221) Except for those errors, the error is returned with data format D.
 Data writing format
Communication request data from the computer to the drive unit 1)
Format
1
2
3
Drive unit
ENQ
station
A


number
Drive unit
ENQ
A1
station


number
Drive unit
ENQ
A2
station


number
Drive unit
ENQ
A3
station


number
Reply data from the drive unit to the computer 3) (No data error detected)
Format
1
2
3
Drive unit
ACK
C
station


number
Drive unit
STX
station
C1


number
Reply data from the drive unit to the computer 3) (With data error)
Number of Characters
Format
1
2
3
Drive unit
NAK
D
station


number

Indicate a control code

Specify the drive unit station numbers between H00 and H1F (stations 0 to 31) in hexadecimal.

When the Pr.123 PU communication waiting time is other than 9999, create the communication request data without "waiting time" in the data format. (The
number of characters decreases by 1.)

CR, LF code
When data is transmitted from the computer to the drive unit, codes CR (carriage return) and LF (line feed) are automatically set at the end of a data group
on some computers. In this case, setting must also be made on the drive unit according to the computer. Whether the CR and LF codes will be present or
absent can be selected using Pr.124 PU communication CR/LF selection.
210
Run
Command
A1
Present
No error
(Request
C
accepted)
With error.
(Request
D
rejected)
No error
(No drive unit
Absent
processing)
With error.
(Drive unit
Absent
outputs 3)
again.)
4
5
6
7
8
Instruction

code
Instruction

Data
code
Instruction

code
Send
Receive
Instruction

data
data
code
type
type
4
5
6
7

Send
Receive
Error
Error
data
data
code
code
type
type
1
2
4
5
Error

code
Operation
Multi
Parameter
speed
command
Write

A, A2
A3
A, A2
Present
Present
Present
C1 
C
D
D
10ms or more
Absent
Absent (C)
Absent
Absent
F
Absent
Number of Characters
9
10
11
12
Data
Sum check

Sum check
Data
Data1
Number of Characters
8
9
10
11
12
Data1
Drive unit
Monitor
reset
A
B
Present
Present
E, E1, E2,
C
C
E3
D
D
D
Absent
Absent (C) Absent (C)
Absent
F
13
14
15
16
17


Sum check
Data2
Sum check
13
14
15
16
17
ETX
Data2
Sum check

Parameter
Read
B
Present
E, E2
D
F
18
19

18
19


Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents