Cc-Link Ie Field Network Basic; Outline; Cc-Link Ie Field Network Basic Configuration - Mitsubishi Electric 800 Series Instruction Manual

Communication
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

2.6

CC-Link IE Field Network Basic

2.6.1

Outline

The CC-Link IE Field Network Basic enables CC-Link IE communication using the general-purpose Ethernet-based
technology. The CC-Link IE Field Network Basic is suited to small-scale equipment for which high-speed control is not
necessary, and can coexist with the standard Ethernet TCP/IP (HTTP, FTP, etc.).
 Communication specifications
The communication specification varies depending on the specification of the master.
Item
Transmission speed
Communication method
Number of connectable units
Connection cable
Number of occupied stations
Maximum number of links per
station
*1
Reference response time
*1
The reference response time is the period from when the inverter receives a command from the master until the inverter returns the response to
the master.
NOTE
• To use the CC-Link IE Field Network Basic, do not install the FR-A8NC E kit to the inverter. (Doing so disables communication
through the CC-Link IE Field Network Basic.)
2.6.2

CC-Link IE Field Network Basic configuration

 Procedure
The following shows the procedure to connect the inverter with a Mitsubishi Electric master device.
 Before communication
1.
Connect each unit with an Ethernet cable. (Refer to
2.
Enter the IP address (Pr.1434 to Pr.1437). (Refer to
3.
Set "61450" in any of Pr.1427 to Pr.1430 Ethernet function selection 1 to 4. (Refer to
4.
Reset the inverter, or turn OFF and then ON the power.
 Registering a profile
1.
Start GX Works3.
2.
On the menu bar, select [Tool] > [Profile Management] > [Register...].
3.
Select a CSP+ file to be registered on the "Register Profile" screen, and click the [Register] button.
NOTE
• A profile is a compressed file (such as *.zip, *.ipar, and *.cspp). Register a profile without decompressing the file.
• Profile registration is not required for the next time onwards.
100 Mbps (10 Mbps is not supported.)
UDP
Master: 1
Slave: up to 16 stations × 4 groups
Ethernet cable
(IEEE 802.3 100BASE-TX compliant cable or ANSI/TIA/EIA-568-B (Category 5)
compliant shielded 4-pair branched cable)
One station occupied
RX
64 (8 bytes)
RY
64 (8 bytes)
RWr
32 (64 bytes)
RWw
32 (64 bytes)
Within 15 ms
Description
page
13.)
page
15.)
page
36.)
2. Ethernet Communication
2.6 CC-Link IE Field Network Basic
1
2
3
4
5
6
7
8
9
10
33