ABB standard macro

This is the default macro. It provides a general purpose I/O configuration with three
constant speeds. Parameter values are the default values given in chapter
signals and
If you use other than the default connections presented below, see section
terminals

Default I/O connections

1...10 kohm
Alternative connection
for AI1. If used, switch
IU selector to U
(0...10 V voltage
signal).
1)
See parameter group
DI3 DI4 Operation (parameter)
0
0 Set speed through integrated
potentiometer
1
0 Speed 1
1 Speed 2
0
1
1 Speed 3
parameters, starting from page 79.
on page 44.
I/O connection
SCR
AI
GND
3)
+10V
+24V
GND
COM
DI1
DI2
DI3
DI4
DI5
Relay connection
COM
NC
NO
12 CONSTANT
SPEEDS:
(1202 CONST SPEED
1)
(1203 CONST SPEED
2)
(1204 CONST SPEED
3)
4)
Signal cable shield (screen)
Frequency reference: 0...20 mA
Analog input circuit common
Reference voltage: +10 V DC, max. 10 mA
Auxiliary voltage output: +24 V DC, max. 200 mA
Auxiliary voltage output common
Digital input common
Stop (0) / Start (1)
Forward (0) / Reverse (1)
Constant speed selection
Constant speed selection
Acceleration and deceleration selection
5)
Relay output
No fault [Fault (-1)]
2)
0 = ramp times according to parameters
ACCELER TIME 1 and
1 = ramp times according to parameters
ACCELER TIME 2 and
3)
360 degree grounding under a clamp.
4)
Tightening torque: 0.22 N·m / 2 lbf·in
5)
Tightening torque: 0.5 N·m / 4.4 lbf·in
1)
1)
2)
2202
2203
DECELER TIME 1.
2205
2206
DECELER TIME 2.
Application macros
71