CODE
FAULT
F0014
EXT FAULT 1
(programmable
fault function,
parameter
3003
EXTERNAL
FAULT 1)
F0015
EXT FAULT 2
(programmable
fault function,
parameter
3004
EXTERNAL
FAULT 2)
F0016
EARTH FAULT
(programmable
fault function,
parameter
3017
EARTH FAULT)
F0017
UNDERLOAD
(programmable
fault function,
parameters
3013...3015)
F0018
THERM FAIL
F0021
CURR MEAS
F0022
INPUT PHASE
LOSS
(programmable
fault function,
parameter
3016
SUPPLY PHASE)
F0026
DRIVE ID
F0027
CONFIG FILE
F0035
OUTP WIRING
(programmable
fault function,
parameter
3023
WIRING FAULT)
F0036
INCOMPATIBLE
SW
F0101
SERF CORRUPT
F0103
SERF MACRO
CAUSE
External fault 1
External fault 2
Drive has detected earth (ground)
fault in motor or motor cable.
Motor load is too low due to, for
example, release mechanism in
driven equipment.
Drive internal fault. Thermistor
used for drive internal temperature
measurement is open or
short-circuited.
Drive internal fault. Current
measurement is out of range.
Intermediate circuit DC voltage is
oscillating due to missing input
power line phase or blown fuse.
Fault trip occurs when DC voltage
ripple exceeds 14% of nominal DC
voltage.
Internal drive ID fault
Internal configuration file error
Incorrect input power and motor
cable connection (that is input
power cable is connected to drive
motor connection).
Fault can be erroneously declared
if drive is faulty or input power is
delta grounded system and motor
cable capacitance is large.
Loaded software is not
compatible.
Corrupted Serial Flash chip file
system
Active macro file missing from
Serial Flash chip
WHAT TO DO
Check external devices for faults.
Check fault function parameter setting.
Check external devices for faults.
Check fault function parameter setting.
Check motor.
Check motor cable. Motor cable length must not
exceed maximum specifications. See section
connection data
on page 144.
Note: Disabling earth fault (ground fault) may
damage drive.
Check for problem in driven equipment.
Check fault function parameter settings.
Check motor power against drive power.
Contact your local ABB representative.
Contact your local ABB representative.
Check input power line fuses.
Check for input power supply imbalance.
Check fault function parameter setting.
Contact your local ABB representative.
Contact your local ABB representative.
Check input power connections.
Contact your local ABB representative.
Contact your local ABB representative.
Contact your local ABB representative.