Syntax
ipv6 netstream timeout inactive seconds
undo ipv6 netstream timeout inactive
Default
The aging timer is 30 seconds for inactive flows.
Views
System view
Predefined user roles
network-admin
Parameters
seconds: Sets the aging timer for inactive flows, in the range of 10 to 600 seconds.
Usage guidelines
A flow is considered inactive if no packet for the IPv6 NetStream entry arrives before the timer set by this
command expires.
Examples
# Set the aging timer to 60 seconds for inactive flows.
<Sysname> system-view
[Sysname] ipv6 netstream timeout inactive 60
Related commands
ipv6 netstream timeout active

reset ipv6 netstream statistics

Use reset ipv6 netstream statistics to age out all flows in the cache and export IPv6 NetStream data.
Syntax
reset ipv6 netstream statistics
Views
User view
Predefined user roles
network-admin
Usage guidelines
It takes the system several minutes to execute the command. During this period, the system does not
perform IPv6 NetStream data collection.
Examples
# Age out and export all IPv6 NetStream data.
<Sysname> reset ipv6 netstream statistics
This process may take a few minutes.
NetStream statistic function is disabled during this process.