Chapter 8: Troubleshooting
4.
Press the Print button to print the list.
You also can print or export a full list of warnings and errors that includes the time each event occurred, even
after you have removed items from the Warnings/Errors list. To do so, follow these steps:
1.
Select the Maintenance tab.
2.
Press the Advanced button.
3.
Press the Warn/Error Out button.
4.
Press either the Print History or Export History button.
If you select Export History, you will be prompted to select the port for export. Press either Serial or
USB to export the list of warnings and errors.
A complete list of warnings and errors is shown below.

Warnings and Error Messages

5 - UV Lamp Warning
Message: "The estimated lamp life is less than 15 days. Order a new UV lamp."
Explanation: Based on the history of usage, the Analyzer estimates that only 10% of the UV lamp life remains.
Order a new UV lamp from GE Analytical Instruments now to avoid down time when the lamp expires.
6 - Tubing Warning
Message: "The estimated tubing life is less than 15 days. Order new tubing."
Explanation: Based on the history of usage, the Analyzer estimates that only 10% of the sample pump tubing life
remains. Order new pump tubing from GE Analytical Instruments now to avoid down time when the tubing
expires.
7 - Resin Bed Warning
Message: "The resin bed life is less than 15 days. Order a new resin bed."
Explanation: Based on the history of usage, the Analyzer estimates that only 10% of the resin bed life remains.
Order a new resin bed from GE Analytical Instruments now to avoid down time when the resin bed expires.
8 - User List Warning
Message: "The user list is nearly full. Archive the user list before adding more users."
Explanation: DataGuard allows a maximum of 100 users. This warning displays when 90 user accounts have
been created.
9 - History Data Warning
Message: "The history data is nearly full. Archive the history data before taking more measurements."
Explanation: The data history can accommodate approximately 33,000 entries (about 90 days of usage). This
warning displays when the data history is 90% full (when approximately 31,941 entries have been saved).
10 - Audit Trail Warning
Message: "The audit trail is nearly full. Archive the audit trail before taking more measurements."
Explanation: The audit trail can accomodate approximately 1,200 entries. This warning displays when the audit
trail is 90% full (when approximately 1,080 entries have been saved).