Control Timer Values (Sec) - Linksys SPA 900 Series Administration Manual

Business series voice system (lvs) ip phones
Hide thumbs Also See for SPA 900 Series:
Table of Contents

Advertisement

Chapter 5
Linksys IP Phone Field Reference
Field
Cadence 1
Cadence 2
Cadence 3
Cadence 4
Cadence 5
Cadence 6
Cadence 7
Cadence 8
Cadence 9

Control Timer Values (sec)

Field
Reorder Delay
(Not applicable to SPA901)
Call Back Expires
Call Back Retry Intvl
Call Back Delay
(Not applicable to SPA901)
Firmware Version 5.1
Description
Cadence script for distinctive ring 1.
Defaults to 60(2/4).
Cadence script for distinctive ring 2.
Defaults to 60(.3/.2, 1/.2,.3/4.
Cadence script for distinctive ring 3.
Defaults to 60(.8/.4,.8/4).
Cadence script for distinctive ring 4.
Defaults to 60(.4/.2,.3/.2,.8/4).
Cadence script for distinctive ring 5.
Defaults to 60(.2/.2,.2/.2,.2/.2,1/4)
Cadence script for distinctive ring 6.
Defaults to60(.2/.4,.2/.4,.2/4).
Cadence script for distinctive ring 7.
Defaults to 60(4.5/4).
Cadence script for distinctive ring 8.
Defaults to 60(0.25/9.75)
Cadence script for distinctive ring 9.
Defaults to 60(.4/.2,.4/2).
Description
Delay after far end hangs up before reorder tone is played. 0 = plays immediately, inf =
never plays. Range: 0–255 seconds.
Defaults to 255.
Expiration time in seconds of a call back activation. Range: 0–65535 seconds.
Defaults to 1800.
Call back retry interval in seconds. Range: 0–255 seconds.
Defaults to 30.
Delay after receiving the first SIP 18x response before declaring the remote end is
ringing. If a busy response is received during this time, the Linksys IP phone still
considers the call as failed and keeps on retrying.
Defaults to 0.5.
Linksys IP Phone Administrator Guide
Regional Tab
5-21

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents