Cisco Catalyst 2950 Command Reference Manual page 228

Desktop switch
Hide thumbs Also See for Catalyst 2950:
Table of Contents

Advertisement

show rps
Table 2-13 show rps Output Description (continued)
Display
ALT_AMBER_BLACK
AMBER
Catalyst 2950 Desktop Switch Command Reference
2-204
Description
The internal power supply in the switch has failed, and the RPS is
providing power to the switch (redundancy has been allocated to this
device).
The RPS is in standby mode, or the RPS has detected a failure.
Press the Standby/Active button on the RPS to put the RPS in active
mode. If the RPS LED on the switch remains amber, the RPS has detected
a failure.
If the failure is minor, the RPS might be in any of the previously
described modes. If the failure is critical, the RPS will be down.
RPS failures include these modes:
The RPS +12V or -48V voltages exceed the specified thresholds.
The RPS has a fan failure.
The RPS detects excessive temperature.
The RPS has a faulty connection to the switch.
Chapter 2 Cisco IOS Commands
78-11381-05

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents