Table 4-25 Logic Prompts; Figure 4-5 Logic Signal Flow - Honeywell VRX180 User Manual

Honeywell video recorder user manual
Table of Contents

Advertisement

Logic
The input or inputs are processed by a logic operator. Call the result of this logic operation "Result".
Result is a pulse that goes ON(1) when the logic is true, and OFF(0) when the logic is not true. Result
is then processed according to the specified condition type and condition time. The final output is a
discrete pulse CVn OS. See Figure 4-5.
Table 4-25 describes the Logic prompts. See Table 4-2 for additional prompts.
Prompt
OPERATOR
AND, OR, XOR, RESET/SET FF,
TOGGLE/FF, ONE SHOT, PASS
INPUT A
OFF, discrete parameter, 0, 1.
INPUT B
INPUT C
INPUT D
INPUT E
INPUT F
INPUT G
INPUT H
CONDITION TYPE
NONE, DELAY, EXTEND, PULSE,
RT PULSE
CONDITION TIME
OFF or number
Inputs
A
B
C
LOGIC
D
E
OPERATOR
F
G
H

Figure 4-5 Logic Signal Flow

Table 4-25 Logic Prompts

Range/Selections
Video Recorder – User Manual
Programming Function Blocks and Features
CONDITION
TYPE
CVn OS
Result
&
CONDITION
TIME
Definition
See Table 4-26.
Program at least 2 inputs. Only inputs
programmed with parameter, 1, or 0 are processed
with the operator.
See Table 4-20 on page 111.
Enter number of seconds of condition time. See
Table 4-20 on page 111.
117

Advertisement

Table of Contents
loading

Table of Contents