Using Snmp - D-Link Unified Access System DWS-3000 Series User Manual

Unified access system
Hide thumbs Also See for Unified Access System DWS-3000 Series:
Table of Contents

Advertisement

To display the commands available in the current mode, enter a question mark (?) at the
command prompt. To display the available command keywords or parameters, enter a
question mark (?) after each word you type at the command prompt. If there are no additional
command keywords or parameters, or if additional parameters are optional, the following
message appears in the output:
<cr>
For more information about the CLI, see the D-Link CLI Command Reference.
The D-Link CLI Command Reference lists each command available from the CLI by the
command name and provides a brief description of the command. Each command reference
also contains the following information:
The command keywords and the required and optional parameters.
The command mode you must be in to access the command.
The default value, if any, of a configurable setting on the device.
The
show
command shows.

Using SNMP

For D-Link WLAN Controller Switch software that includes the SNMP module, you can
configure SNMP groups and users that can manage traps the SNMP agent generates.
The D-Link WLAN Controller Switch uses both standard public MIBs for standard
functionality as well as a number of additional private MIBs for additional functionality
supported by the switch. All private MIBs begin with a "DLINK-" prefix. The main object for
interface configuration is in DLINK-SWITCHING-MIB, which is a private MIB. Some
interface configurations also involve objects in the public MIB, IF-MIB.
SNMP is enabled by default. The System Description Web page, which is the page the
displays after a successful login, and the
need to configure an SNMP manager to access the switch.
Any user can connect to the switch using the SNMPv3 protocol, but for authentication and
encryption, you need to configure a new user profile. To configure a profile by using the CLI,
see the SNMP section in the D-Link CLI Command Reference. To configure an SNMPv3
profile by using the Web interface, use the following steps:
1. Select LAN > Administration > User Accounts from the hierarchical tree on the left side
of the Web interface.
2. Using the User pull-down menu, select Create to create a new user.
3. Enter a new user name in the User Name field.
4. Enter a new user password in the Password field and then retype it in the Confirm
Password field.
To use SNMPv3 Authentication for this user, set a password of eight or more
alphanumeric characters.
5. To enable authentication, use the Authentication Protocol pull-down menu to select
either MD5 or SHA for the authentication protocol.
Press Enter to execute the command
commands in the document also include a description of the information that the
1 Overview of the D-Link Unified Access System
command display the information you
show sysinfo
Understanding the User Interfaces
27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dwl-3500ap8500apDwl-8500ap

Table of Contents