6-3-3. BAT-UNIT, LCD-UNIT
BAT-UNIT
(1) Disconnect the connector (1 place).
(2) Undo 2 screws (S3).
(3) Remove the BAT-UNIT.
[ NOTE ] It is stuck with double-sided tape.
LCD-UNIT
[ Major parts ] LCD-MODULE, LCD-HOLDER, COIL-SPRING
(1) Release the connector lock and remove the FPC (1 place).
(2) Remove the LCD-UNIT.
[ NOTE ] The COIL-SPRINGs (3 places) can come off . In this case, do not lose them.
[ Notes on reassembling ]
(1) Pass the LCD-FPC through the slit in the LCD-HOLDER as shown below.
(2)
Check that COIL-SPRINGs (3 places) are attached in place and then assemble the LCD-UNIT.
FPC (LCD)
CN (BAT-UNIT)
Double-sided tape
COIL-SPRINGs
LCD-MODULE
COIL-SPRINGs
– 76 –
IT-9000
BAT-UNIT
Screws (S3)
LCD-HOLDER