Casio IT-9000 Series Service Manual page 56

Hide thumbs Also See for IT-9000 Series:
Table of Contents

Advertisement

ALL TEST MENU-6
[1] Current - Run mode
No.
Operation
Select "[1].Current - Run
Mode" from MENU-6 screen.
1
[2] Current - Sleep mode
No.
Operation
Select "[2].Current - Sleep
Mode" from MENU-6 screen.
1
[6] Current - 2D Scanner (2D type only)
No.
Operation
Select "[6].Current - 2D
Scanner" from MENU-6
screen.
1
Display
Display
Display
– 49 –
IT-9000
Test Details
Automatically judges if the
current value is within 100 to
200 mA.
For Model-C: 80 to 200 mA
If OK.
The screen returns to the menu
screen.
If out of range (Failure):
An error indication is displayed.
Press the "ENT" key to return to
the menu screen.
Test Details
Automatically judges if the
current value is within 30 to 110
mA.
For Model-C: 110 mA or less
If OK.
The screen returns to the menu
screen.
If out of range (Failure):
An error indication is displayed.
Press the "ENT" key to return to
the menu screen.
Test Details
Automatically judges if the
current value is within 200 to
300 mA.
For Model-C: 220 to 360 mA
If OK.
The screen returns to the menu
screen.
If out of range (Failure):
An error indication is displayed.
Press the "ENT" key to return to
the menu screen.

Advertisement

Table of Contents
loading

Table of Contents